SLUSG35 August 2026 TPS12S24F-Q1
ADVANCE INFORMATION
The TPS12SxxF-Q1 device senses SRCx pin voltage and provides an output voltage measurement per channel through the integrated 10-bit ADC. The output voltage measurement function is disabled by default. To enable the output voltage sense function it needs to be globally enabled in the ADC_CONFIG register through the ADC_VSNS_DIS bit. If the global bit is enabled then the device will enable the output voltage measurement on each channel according to the VSNS_DIS_CHx bit in the respective CHx_CONFIG register.
The conversion equation for the output voltage measurement is detailed in Equation. The ADC measurement result will be available in the ADC_RESULT_CHx_V register. The VSNS_RDY_CHx bit is set to 1 if a new ADC conversion result exists since the register was last read.