SLUUDM5 March 2026 MSPM0G1507 , MSPM0G1519 , MSPM0G3507 , MSPM0G3519
Align method is a basic start method of sensorless FOC control algorithm. It is implemented to obtain an accurate initial position of the motor rotor. Set mtrStartUpOption as 0h to select align mode.
Follow the steps below to tune the align mode parameters: