SLUUDM5 March 2026 MSPM0G1507 , MSPM0G1519 , MSPM0G3507 , MSPM0G3519
Double align method avoids the marginally stability state that occurs during motor alignment when the motor rotor position differs from the alignment angle by 180 electrical degrees.
FOC application does not support double align mode, setting mtrStartUpOption to 1h also represents align mode.