SLUUDM5 March 2026 MSPM0G1507 , MSPM0G1519 , MSPM0G3507 , MSPM0G3519
For three or dual shunt configurations, FOC application converts phase currents one time in one PWM period. The ADC instance used for phase current sampling must set and only set the last ADC memory Index with Valid Trigger mode. So that in every PWM period cycle, PWM module generates an event to ADC module when low side MOSFET all ON, and this event triggers ADC to sample and convert phase currents. The following figure shows the SysConfig setting of sensorless-foc_DRV8316 project.