SLUUDM5 March 2026 MSPM0G1507 , MSPM0G1519 , MSPM0G3507 , MSPM0G3519
FOC application start the ADC conversion by a hardware event generated by PWM module to avoid software delay. The ADC repeat mode is used with valid trigger mode to implement periodically conversion in every PWM cycle. The following table introduces the difference between auto step and valid trigger mode.
| ADC Trigger Mode | Description |
|---|---|
| Auto step to next conversion | When ADC finishes current memory conversion, it automatically steps to next memory and starts conversion. |
| Valid trigger to next conversion | When ADC finishes current memory conversion, it waits for another trigger signal to start conversion at next memory. If no trigger signal occurs, ADC stays at current ADC memory and with no operation. |
Follow the steps below to set proper trigger mode of the ADC channels for FOC application.