SNAU308A November 2024 – May 2025
Category 1b and Category 2 SYNC requires putting the LMX device in SYNC mode. That means, VCO_PHASE_SYNC = 1. Please note, in SYNC mode, the maximum fPD is 50MHz.
For Category 1b SYNC, enabling SYNC mode is sufficient. After programming the devices, the output phases are all be aligned.
For Category 2 SYNC, in addition to putting the devices in SYNC mode, a non-time-critical SYNC pulse is required to trigger all devices to synchronize. The SYNC pulse can be given by an external source or by toggling the SYNC pin LOW-HIGH-LOW. Click the Toggle Sync pin button toggles the SYNC pin L-H-L once.
Figure 4-33 Category 1b SYNC
Figure 4-34 Category 2 SYNC