SBASAE3 December 2025 ADS125H18
PRODUCTION DATA
Good power-supply decoupling is important to achieve optimum device performance. As shown in Figure 8-13, AVDD, IOVDD and CAPD must each be decoupled with at least a 1μF capacitor to GND. Also, AVDD, CAPA, REFOUT and REFP must be bypassed with a 1μF capacitor to AVSS. Place the supply bypass capacitors as close to the device power-supply pins as possible using low-impedance connections. Use multi-layer ceramic chip capacitors (MLCCs) that offer low equivalent series resistance (ESR) and inductance (ESL) characteristics for power-supply decoupling purposes. For very sensitive systems, or for systems in harsh noise environments, avoiding the use of vias for connecting the capacitors to the device pins can offer superior noise immunity. The use of multiple vias in parallel lowers the overall inductance and is beneficial for connections to ground planes.