SBASAE3 December 2025 ADS125H18
PRODUCTION DATA
The conversion counter CONV_COUNT[3:0]) increments every time a new conversion completes. After reaching a counter value of Fh, the counter rolls over to 0h with the completion of the next conversion.
The counter only resets to Fh in powerdown mode, after a device reset, or when writing to the SEQUENCER_CFG register. At the same time the sequence step indicator (STEP_INDICATOR[4:0]) resets to 00h, the sequence counter (SEQ_COUNT[3:0]) resets to 0h, and the conversion data clears. At the completion of the first conversion after reset, powerdown, or after writing to the SEQUENCER_CFG register, the counter reads 0h. When the sequencer is enabled (SEQ_MODE[1:0] = 10b or 11b), the counter always reads 0h for the first conversion of a step. When the sequencer is disabled (SEQ_MODE[1:0] = 00b or 01b), the counter value does not return to 0h if conversions with a new step page configuration complete.
When the conversion counter is output as part of the STATUS header (STATUS_EN = 1b), the device makes sure that the conversion counter value always matches to the ADC conversion result that is output in the same SPI frame.
Reset the counter to Fh by writing to the SEQUENCER_CFG register before starting a conversion with a new step page configuration if desired.