Setting the SEQ_MODE[1:0] bits in the SEQUENCER_CFG register to 10b selects the single sequence mode (sequencer enabled). In this mode, the device executes each enabled sequence step one time. The STEP_INIT[4:0] bits in the CONVERSION_CTRL register point to the first sequence step x_initial (x = 0 to 31) to be executed:
Figure 7-21 shows a flow chart of the sequencer operation, including the behavior in single sequence mode (SEQ_MODE[1:0] = 10b).
Enable sequence steps by setting the corresponding SEQ_STEP_x_EN bit (x = 0 to 31) in the SEQUENCE_STEP_EN registers to 1b. If the first sequence step as defined by STEP_INIT[4:0] is not enabled, sequencing is not started. If the first enabled sequence step x_inital is not equal to 0, then only steps from x_inital to 31 are executed in this mode, and steps smaller than x_inital are ignored even if enabled. For example, if x_inital = 20, and all steps are enabled, only steps 20 to 31 are executed.
For each enabled sequence step, the device configures the ADC based on the step configuration page x, adds the programmable delay time defined by the STEPx_DELAY[15:0] bits and starts ADC conversions. The number of ADC conversions for the step is set by the STEPx_NUM_CONV[3:0] bits in the STEPx_ADC_REF_CFG register. Up to 512 ADC conversion results can be sampled. Afterwards the device proceeds to the next enabled sequence step.
To stop the sequencer and discontinue the ADC conversions, set the STOP bit to 1b. See the Starting and Stopping the Sequencer section for details on stopping the sequencer, and details on the stop behavior defined by the STOP_BEHAVIOR[1:0] bits.
After the last conversion of the last sequence step completed, the device enters standby mode (STBY_MODE = 1b) or remains fully powered in idle mode (STBY_MODE = 0b).