SLVSIL5A May 2025 – September 2025 UCC25661-Q1
PRODUCTION DATA
In UCC25661x-Q1 family, a new soft start is implemented to control the inrush current at start up. The new scheme avoids premature soft start termination and provides smooth transition between soft start and closed loop regulation.
At start up, internal Soft start voltage (SSRamp) ramps up using a defined slope and the FBReplica is as high as the output voltage is, below the regulation voltage. The lower of the two signals determines the turn-off control of the power stage switches.
The soft start is exited only after the SSRamp is above a minimum threshold, avoiding any premature soft start exit.