To maximize efficiency, a bias winding is required to use the high-voltage start-up function. Design the bias winding so that the VCCP voltage is greater than 12V. The > 12V VCCP voltage is not required for the UCC256613 where an external auxiliary bias supply is expected to power VCCP.
Build or purchase the transformer according to these specifications:
For some applications that operate as a wide input LLC where the PFC can shut off in standby mode, the operating frequency can be much lower during heavy load shutdown. The LLC operates at just above the ZCS boundary, which is a lower frequency. Rate the magnetic components in the resonant circuit, transformer, and resonant inductor, to operate at a lower frequency.
The bias voltage is obtained as 18V, as per the turns ratio. To reduce the controller voltage to 15V, use a voltage regulator circuit in the EVM before supplying to the VCCP of the controller.