SLVSIL5A May 2025 – September 2025 UCC25661-Q1
PRODUCTION DATA
The AC voltage across the resonant inductor is calculated using the AC voltage across the resonant inductor impedance multiplied by the current:
Build or purchase the inductor according to the following specifications:
Some designs use the leakage inductance of the transformer as the resonant inductance and do not require an external resonant inductor which can save cost and space. However, consult a magnetics vendor to determine if the design required an external resonant inductor.