7-6 |
TOPOFF_TMR_1:0 |
R/W |
0h |
Reset by:
WATCHDOG
REG_RST
|
Top-off timer control
Type : RW
POR: 00b
0h = Disabled (default)
1h = 15 mins
2h = 30 mins
3h = 45 mins
|
5 |
EN_TRICHG_TMR |
R/W |
1h |
Reset by:
WATCHDOG
REG_RST
|
Enable trickle charge timer (fixed as 1hr)
Type : RW
POR: 1b
0h = Disabled
1h = Enabled (default)
|
4 |
EN_PRECHG_TMR |
R/W |
1h |
Reset by:
WATCHDOG
REG_RST
|
Enable pre-charge timer
Type : RW
POR: 1b
0h = Disabled
1h = Enabled (default)
|
3 |
EN_CHG_TMR |
R/W |
1h |
Reset by:
WATCHDOG
REG_RST
|
Enable fast charge timer
Type : RW
POR: 1b
0h = Disabled
1h = Enabled (default)
|
2-1 |
CHG_TMR_1:0 |
R/W |
2h |
Reset by:
WATCHDOG
REG_RST
|
Fast charge timer setting
Type : RW
POR: 10b
0h = 5 hrs
1h = 8 hrs
2h = 12 hrs (default)
3h = 24 hrs
|
0 |
TMR2X_EN |
R/W |
1h |
Reset by:
WATCHDOG
REG_RST
|
TMR2X_EN
Type : RW
POR: 1b
0h = Trickle charge, pre-charge and fast charge timer NOT slowed by 2X during input DPM or thermal regulation.
1h = Trickle charge, pre-charge and fast charge timer slowed by 2X during input DPM or thermal regulation (default)
|