7 |
RESERVED |
R |
0h |
|
RESERVED |
6 |
DPDM_DONE_MASK |
R/W |
0h |
Reset by:
REG_RST
|
D+/D- detection is done mask flag
Type : RW
POR: 0b
0h = D+/D- detection done does produce INT pulse
1h = D+/D- detection done does NOT produce INT pulse
|
5 |
ADC_DONE_MASK |
R/W |
0h |
Reset by:
REG_RST
|
ADC conversion mask flag (only in one-shot mode)
Type : RW
POR: 0b
0h = ADC conversion done does produce INT pulse
1h = ADC conversion done does NOT produce INT pulse
|
4 |
VSYS_MASK |
R/W |
0h |
Reset by:
REG_RST
|
VSYS min regulation mask flag
Type : RW
POR: 0b
0h = enter or exit VSYSMIN regulation does produce INT pulse
1h = enter or exit VSYSMIN regulation does NOT produce INT pulse
|
3 |
CHG_TMR_MASK |
R/W |
0h |
Reset by:
REG_RST
|
Fast charge timer mask flag
Type : RW
POR: 0b
0h = Fast charge timer expire does produce INT
1h = Fast charge timer expire does NOT produce INT
|
2 |
TRICHG_TMR_MASK |
R/W |
0h |
Reset by:
REG_RST
|
Trickle charge timer mask flag
Type : RW
POR: 0b
0h = Trickle charge timer expire does produce INT
1h = Trickle charge timer expire does NOT produce INT
|
1 |
PRECHG_TMR_MASK |
R/W |
0h |
Reset by:
REG_RST
|
Pre-charge timer mask flag
Type : RW
POR: 0b
0h = Pre-charge timer expire does produce INT
1h = Pre-charge timer expire does NOT produce INT
|
0 |
TOPOFF_TMR_MASK |
R/W |
0h |
Reset by:
REG_RST
|
Top off timer mask flag
Type : RW
POR: 0b
0h = Top off timer expire does produce INT
1h = Top off timer expire does NOT produce INT
|