Figure 8-10 illustrates a 2-terminal, differential analog input module (AIM), using a discrete burden resistor for the 4-20mA measurement and a high-resistive switching element (solid-state or semiconductor) to switch between current and voltage measurement mode.
To eliminate the error from the select switch on-resistance, a third ADC input is utilized to measure the positive terminal of the burden resistor (meaning, the node between burden and switch) for every channel. For example on channel 1, the voltage measurement is taken by sampling the differential voltage between AIN0 and AIN2, and the current measurement is taken by sampling the differential voltage between AIN1 and AIN2 as shown in Figure 8-10.
IIn this circuit, the voltage measured by the ADC is independent from the switch resistance. Instead of Equation 34, the equation is now given by:
Therefore, the overall measurement error for the current input is reduced, compared to a circuit which includes a select switch, see Table 8-4.
Three ADC inputs are used per V/I differential input channel in this architecture. Therefore, a maximum of 4 differential analog inputs can be implemented using one ADS125H18 device.