SNAS264D April 2006 – February 2024 LM94
PRODUCTION DATA
| Register Address | Read/ Write | Register Name | Bit 7 | Bit 6 | Bit 5 | Bit 4 | Bit 3 | Bit 2 | Bit 1 | Bit 0 | Default Value |
|---|---|---|---|---|---|---|---|---|---|---|---|
| CCh | R/W | PWM2 Control 1 | VRD2 | VRD1 | PH2 | PH1 | LUT4 | LUT3 | LUT2 | LUT1 | 00h |
| Bit | Name | R/W | Description |
|---|---|---|---|
| 0 | LUT1 | R/W | If set, PWM2 will be bound to LUT 1. |
| 1 | LUT2 | R/W | If set, PWM2 will be bound to LUT 2. |
| 2 | LUT3 | R/W | If set, PWM2 will be bound to LUT 3. |
| 3 | LUT4 | R/W | If set, PWM2 will be bound to LUT 4. |
| 4 | PH1 | R/W | If set, PWM2 will be bound to P1_PROCHOT. |
| 5 | PH2 | R/W | If set, PWM2 will be bound to P2_PROCHOT. |
| 6 | VRD1 | R/W | If set, PWM2 will be bound to VRD1_HOT. |
| 7 | VRD2 | R/W | If set, PWM2 will be bound to VRD2_HOT. |
This register can bind PWM2 to several different control sources. The temperature zones control the PWM duty cycle using the table lookup function. The Px_PROCHOT and VRDx_HOT inputs control the PWM using the ramp up/ramp down functions. If multiple control sources are bound to PWM2, the largest duty cycle being requested will be used.