SNAS264D April 2006 – February 2024 LM94
PRODUCTION DATA
| Register Address | Read/ Write | Register Name | Bit 7 | Bit 6 | Bit 5 | Bit 4 | Bit 3 | Bit 2 | Bit 1 | Bit 0 | Default Value |
|---|---|---|---|---|---|---|---|---|---|---|---|
| CAh | R/W | PWM1 Control 3 | SU_DUR[2:0] | SU_DUR[3] | SU_DC | 00h | |||||
| Bit | Name | R/W | Description |
|---|---|---|---|
| 3:0 | SU_DC | R/W | This field sets the duty cycle that will be used whenever PWM1 experiences a Spin-Up cycle. This field accepts 16 possible values that are mapped to duty cycles according the table in the Section 6.2.18.2 section. Setting this field to 0h will effectively disable Spin-Up. |
| 4 | SU_DUR[3] | R/W | Most significant bit that sets the Spin-up duration for PWM1. |
| 7:0 | SU_DUR[2:0] | R/W | Least significant bits that set the Spin-Up duration for PWM1 least significant bits. |
Bits 7:4 configure the spin-up duration. When the duty cycle of PWM1 changes from zero to a non-zero value, the spin-up sequence is activated for the specified amount of time. The available settings are defined according to this table:
| SU_DUR[3] (Bit 4) | SU_DUR[2:0] (Bits[7:5]) | Spin-Up Time |
|---|---|---|
| 0 | 0h | Spin-up disabled |
| 0 | 1h | 100 ms |
| 0 | 2h | 250 ms |
| 0 | 3h | 400 ms |
| 0 | 4h | 700 ms |
| 0 | 5h | 1s |
| 0 | 6h | 2 s |
| 0 | 7h | 4 s |
| 1 | 0h | 6 s |
| 1 | 1h | 8 s |
| 1 | 2h | 10 s |
| 1 | 3h | 12 s |
| 1 | 4h | 14 s |
| 1 | 5h | 16 s |
| 1 | 6h | 18 s |
| 1 | 7h | 20 s |