Home Energiemanagement Leistungsschutzschalter und Controller eFuses (integrierte Hot-Swaps)
NEU

TPS1689

AKTIV

Stapelbare eFuse mit digitaler PMBus®-Telemetrie, 9 V bis 80 V, 3,5 mΩ, 20 A

Produktdetails

Vabsmax_cont (V) 92 Vin (max) (V) 80 Vin (min) (V) 9 Current limit (max) (A) 20 Current limit (min) (A) 2 Features Adjustable current limit, Adjustable soft start, Current monitoring, Fault output, Overcurrent protection, Overvoltage protection, PMBus, Power good signal, Short-circuit protection, Thermal shutdown Overcurrent response Circuit breaker Fault response Auto-retry, Latch-off Ron (typ) (mΩ) 3.5 Overvoltage response Cut-off Rating Catalog Soft start Adjustable Quiescent current (Iq) (typ) (A) 0.004 Device type eFuses and hot swap controllers Operating temperature range (°C) -40 to 125
Vabsmax_cont (V) 92 Vin (max) (V) 80 Vin (min) (V) 9 Current limit (max) (A) 20 Current limit (min) (A) 2 Features Adjustable current limit, Adjustable soft start, Current monitoring, Fault output, Overcurrent protection, Overvoltage protection, PMBus, Power good signal, Short-circuit protection, Thermal shutdown Overcurrent response Circuit breaker Fault response Auto-retry, Latch-off Ron (typ) (mΩ) 3.5 Overvoltage response Cut-off Rating Catalog Soft start Adjustable Quiescent current (Iq) (typ) (A) 0.004 Device type eFuses and hot swap controllers Operating temperature range (°C) -40 to 125
LQFN-CLIP (VMA) 23 30 mm² (5 mm × 6 mm)
  • Input operating voltage range: 9V to 80V
    • 92V absolute maximum rating
    • Withstands negative transient voltages up to –5V at output
  • Integrated FET with low ON-resistance
    • RON = 3.5mΩ (typ)
  • PMBus interface for telemetry, control, configuration, and debug
    • PIN/EIN/VIN/VOUT/IIN temperature and fault monitoring
    • VIN/VOUT monitoring accuracy: ±0.5%
    • Programmable overcurrent protection
      • Adjustable overcurrent threshold: 2A to 20A
      • Programmable transient overcurrent timer (OC_TIMER)
    • Programmable slew rate control (dvdt)
    • Programmable Power Good/fault/alert indication
    • Programmable overtemperature protection
    • Internal non-volatile memory for user configuration
    • Blackbox fault recording with option to store in external EEPROM
  • Fast trip response to severe overcurrent (short-circuit) events
  • Precise analog load current monitoring (IMON)
    • <1% error over 50% to 100% of max current

      (TA = 25°C)

  • Small footprint: QFN 6mm × 5mm
    • IPC9592B clearance for 60V
  • Input operating voltage range: 9V to 80V
    • 92V absolute maximum rating
    • Withstands negative transient voltages up to –5V at output
  • Integrated FET with low ON-resistance
    • RON = 3.5mΩ (typ)
  • PMBus interface for telemetry, control, configuration, and debug
    • PIN/EIN/VIN/VOUT/IIN temperature and fault monitoring
    • VIN/VOUT monitoring accuracy: ±0.5%
    • Programmable overcurrent protection
      • Adjustable overcurrent threshold: 2A to 20A
      • Programmable transient overcurrent timer (OC_TIMER)
    • Programmable slew rate control (dvdt)
    • Programmable Power Good/fault/alert indication
    • Programmable overtemperature protection
    • Internal non-volatile memory for user configuration
    • Blackbox fault recording with option to store in external EEPROM
  • Fast trip response to severe overcurrent (short-circuit) events
  • Precise analog load current monitoring (IMON)
    • <1% error over 50% to 100% of max current

      (TA = 25°C)

  • Small footprint: QFN 6mm × 5mm
    • IPC9592B clearance for 60V

The TPS1689x is an integrated high current circuit protection and power management solution in a small package. The device provides multiple protection modes using very few external components and is a robust defense against overloads, short circuits and excessive inrush current. The integrated PMBus interface allows a host controller to monitor, control and configure the system in real-time. Key system parameters can be read back for remote telemetry. Various protection/warning thresholds and coefficients can be configured through PMBus or stored in non-volatile configuration memory. An integrated fast and accurate sense analog load current monitor facilitates predictive maintenance and advanced dynamic platform power management such as Intel PSYS and PROCHOT to optimize server and data-center performance. Blackbox fault recording feature helps in debug of field failure/returns. For higher current support, TPS1689x can be connected in parallel with TPS1685x. The devices are characterized for operation over a junction temperature range of –40°C to +125°C.

The TPS1689x is an integrated high current circuit protection and power management solution in a small package. The device provides multiple protection modes using very few external components and is a robust defense against overloads, short circuits and excessive inrush current. The integrated PMBus interface allows a host controller to monitor, control and configure the system in real-time. Key system parameters can be read back for remote telemetry. Various protection/warning thresholds and coefficients can be configured through PMBus or stored in non-volatile configuration memory. An integrated fast and accurate sense analog load current monitor facilitates predictive maintenance and advanced dynamic platform power management such as Intel PSYS and PROCHOT to optimize server and data-center performance. Blackbox fault recording feature helps in debug of field failure/returns. For higher current support, TPS1689x can be connected in parallel with TPS1685x. The devices are characterized for operation over a junction temperature range of –40°C to +125°C.

Herunterladen Video mit Transkript ansehen Video

Technische Dokumentation

Keine Ergebnisse gefunden. Bitte geben Sie einen anderen Begriff ein und versuchen Sie es erneut.
Alle anzeigen 4
Top-Dokumentation Typ Titel Format-Optionen Neueste englische Version herunterladen Datum
* Datenblatt TPS1689x 9V to 80V, 3.5mΩ, 20A Stackable Integrated Hotswap (eFuse) With PMBus Digital Telemetry datasheet (Rev. A) PDF | HTML 11.12.2025
Anwendungshinweis Active Current Sharing: Advanced Current Distribution Feature From TI's Smart eFuses PDF | HTML 09.05.2025
Anwendungshinweis Enhancing Server Power Design Using Advanced Features of TI’s Smart eFuses PDF | HTML 29.01.2025
Zertifikat TPS1689EVM EU Declaration of Conformity (DoC) PDF | HTML 31.10.2024

Design und Entwicklung

Weitere Bedingungen oder erforderliche Ressourcen enthält gegebenenfalls die Detailseite, die Sie durch Klicken auf einen der unten stehenden Titel erreichen.

Evaluierungsplatine

TPS1689EVM — TPS1689 – Evaluierungsmodul

Das TPS1685EVM wird verwendet, um die Leistung des TPS1685 eFuse-Bausteins zu evaluieren. Das TPS1685EVM wird mit zwei parallel geschalteten TPS16851-eFuses geliefert, um ein 54-V-Design (typisch) und ein 40-A-Design (stationärer Zustand) zu evaluieren. Dieses Evaluierungsmodul umfasst zwei (...)
Benutzerhandbuch: PDF | HTML
Unterstützte Produkte und Hardware
Vorrätig
Limit:
??asset.out-of-stock-ti_de_DE??
Nicht verfügbar
GUI für Evaluierungsmodul (EVM)

TPS1689-EVM-GUI — TPS1689 evaluation module GUI

The GUI allows the customer to configure, control, and view telemetry data from the TPS1689 eFuse.
Unterstützte Produkte und Hardware
Simulationsmodell

TPS1685 PSpice Transient Model

SLVMED5.ZIP (68 KB) - PSpice-Modell
Unterstützte Produkte und Hardware
Simulationsmodell

TPS16851 PSpice Transient Model

SLVMED3.ZIP (66 KB) - PSpice-Modell
Unterstützte Produkte und Hardware
Berechnungstool

TPS1689-CALC — TPS1689 Design Calculator

The design calculator allows customer to size the external peripheral components while designing with TPS1689 eFuse.
Unterstützte Produkte und Hardware
Berechnungstool

TVS-RECOMMENDATION-CALC — TVS diode recommendation tool

This tool suggests suitable TVS for given system parameters and abs max voltage rating of the device.
Unterstützte Produkte und Hardware
Referenzdesign

TIDA-050090 — Referenzdesign m. Leistungszweigschutz (54 V, 5 kW) f. KI-Rechenzentren m. eFuses TPS1689 u. TPS1685

Dieses Referenzdesign zeigt einen Eingangsleistungszweig-Schutzschaltkreis mit 54 V und 5 kW für KI-gestützte Rechenzentren unter Verwendung von einem bzw. fünf parallel geschalteten eFuse-Bausteinen der Reihe TPS1689 und TPS1685. Diese integrierten Hochstrom-Schaltkreisschutzbausteine bieten (...)

Unterstützte Produkte und Hardware
Gehäuse Pins CAD-Symbole, Footprints und 3D-Modelle
LQFN-CLIP (VMA) 23 Ultra Librarian

Bestellen & Qualität

Empfohlene Produkte können Parameter, Evaluierungsmodule oder Referenzdesigns zu diesem TI-Produkt beinhalten.

Support und Schulungen

TI E2E™-Foren mit technischem Support von TI-Ingenieuren

Inhalte werden ohne Gewähr von TI und der Community bereitgestellt. Sie stellen keine Spezifikationen von TI dar. Siehe Nutzungsbedingungen.

Bei Fragen zu den Themen Qualität, Gehäuse oder Bestellung von TI-Produkten siehe TI-Support. ​​​​​​​​​​​​​​

Videos