The VCC2 pin provides 5V with up
to 200mA to external circuitry and requires an external capacitor to ground. The
VCC2 pin is short to battery protected and if connected to VCAN or an
external CAN transceiver, do not take the VCC2 off board where a short to battery can
take place. There are three monitors on VCC2, under-voltage (UVCC2),
over-voltage (OVCC2) and short to ground (VCC2SC). When these faults are
detected an interrupt is provided and the LDO may or may not be turned off. No mode
change take place. When VCC2 is on and not in a fault state, register 8'h4F[2],
VCC2_STATUS, indicates this by being set to 1b.