SLLSFO8C May 2024 – November 2025 TCAN2450-Q1 , TCAN2451-Q1
PRODUCTION DATA
The TCAN245x-Q1 has a watchdog error counter. This counter is an up down counter that increments for every missed window or incorrect input watchdog trigger event. For every correct input trigger, the counter decrements but does not drop below zero. The default trigger for this counter is to trigger a watchdog event is for every event. This counter can be configured at register 8'h16[7:4] which sets the limit for incorrect input triggers up to 15. The error counter can be read at register 8'14[4:1].
Once the programmed WD error counter limit has been exceeded, the device transitions to restart mode which pulls nRST low for tNRST_TOG. The error counter resets back to 0 at this point. Once tNRST_TOG times out, the device transitions back to standby mode releasing nRST high. If the WD failure causes the restart counter to exceed its programmed limit, the device transitions to either fail-safe mode if enabled or to sleep mode.