TCAN245x-Q1monitors VCC1 and VCC2 for over-voltage condition. Over-voltage is represented by OVCC1 and OVCC2. If OVCC1_ACTION (8'h0C[6]) is 0b (default) and OVCC1 occurs, VCC1 is turned-off and the device enters either fail-safe mode, if enabled, or sleep mode. The device can be configured to only set an OVCC1 interrupt and not enter fail-safe or sleep mode by setting OVCC1_ACTION to 1b. When OVCC2 takes place, the LDO is turned off and an interrupt flag is set but no mode change takes place. When entering fail-safe mode, the device turns off all the regulators and starts the t
REGOFF timer. After this timer times out, OVCC1 is checked for over-voltage. If the OV event has cleared, and a wake event has taken place, the device enters restart mode. If OVCC1 is still present, the device remains in fail-safe mode. Wake events are monitored but not acted upon until t
REGOFF time out. If no wake event has taken place and the OV event has cleared, the device is still in fail-safe mode until the SWE timer times out or a wake event takes place. See
Figure 8-34 and
Figure 8-35 for device behavior during an over-voltage event.