SLVSHO1A March 2025 – December 2025 TPS1689
PRODUCTION DATA
The TPS1689x implements overvoltage lockout to protect the load from input overvoltage conditions. If the input voltage on IN exceeds the OVP rising threshold, the power FET is turned OFF within tOVP. The OVP comparator on the IN pin uses a default internal overvoltage protection threshold of VOVP(R), which can be changed by programming the non-volatile configuration memory or dynamically through PMBus® register writes to the VIN_OV_FLT register. The OVP comparator has in-built hysteresis for improved noise immunity. When the voltage at IN falls back below the OVP falling threshold (VOVP(F)), the device selects the turn on mode based on the duration of the overvoltage condition. If the overvoltage condition persists for more than 20 µs, the FET turns ON in a controlled dVdt manner. If the overvoltage condition lasts for less than 20 µs, the FET turns ON in fast recovery mode.
Figure 7-3 Input Overvoltage Protection Response