JAJSS15 November 2023 LMK3H0102
ADVANCE INFORMATION
Do not tie VDD and VDDO pins to ground. Use a separate ferrite bead to isolate the VDD and the VDDO supplies. If OUT0 and OUT1 are different frequencies, a separate ferrite bead must be used for each VDDO supply. For each supply voltage pin, a 0.1-µF or 1-µF capacitor must be placed very close to the pin.