SLASFM1A June 2025 – December 2025 AFE10004-EP
PRODUCTION DATA
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| RESERVED | RESERVED | LUTSTAT | LUTDIS | LUTSEL2 | LUTSEL1 | REN | LEN |
| R-0h | R-0h | R-0h | R/W-0h | R/W-0h | R/W-0h | R/W-1h | R/W-1h |
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| BYP3 | BYP2 | BYP1 | BYP0 | DAC3OW | DAC2OW | DAC1OW | DAC0OW |
| R-0h | R-0h | R-0h | R/W-0h | R/W-0h | R/W-0h | R/W-1h | R/W-1h |
| LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 13 | LUTSTAT | R | 0h | LUT status indicator 0 = The LUT/ALU engine is disabled. 1 = The LUT/ALU engine is enabled. |
| 12 | LUTDIS | R/W | 0h | LUT/ALU control 0 = Enables the LUT/ALU engine. 1 = Disables the LUT/ALU engine. The temperature sensor remains active. The LUT/ALU engine must be disabled during EEPROM access or register access to pages 4, 5 and 15. |
| 11 | LUTSEL2 | R/W | 0h | LUT2 and LUT3 temperature input 0 = Local temperature sensor. 1 = Remote temperature sensor. |
| 10 | LUTSEL1 | R/W | 0h | LUT0 and LUT1 temperature input 0 = Local temperature sensor. 1 = Remote temperature sensor. |
| 9 | REN | R/W | 1h | Remote temperature sensor control 0 = Disables remote temperature sensor conversions. 1 = Enables remote temperature sensor conversions. |
| 8 | LEN | R/W | 1h | Local temperature sensor control 0 = Disables local temperature sensor conversions. 1 = Enables local temperature sensor conversions. |
| 7 | BYP3 | R/W | 0h | DACx ALU bypass control 0 = ALU output sent to DACx. 1 = Bypass the ALU output. Send BASEx value to DACx. |
| 6 | BYP2 | R/W | 0h | |
| 5 | BYP1 | R/W | 0h | |
| 4 | BYP0 | R/W | 0h | |
| 3 | DAC3OW | R/W | 0h | DACx overwrite control 0 = DACx input is generated by LUT. 1 = DACx input is supplied by the serial interface accessible DACxOW[12:0] data register. |
| 2 | DAC2OW | R/W | 0h | |
| 1 | DAC1OW | R/W | 0h | |
| 0 | DAC0OW | R/W | 0h |