SLASFM1A June 2025 – December 2025 AFE10004-EP
PRODUCTION DATA
Unless a different configuration has been burned in the EEPROM, autonomous operation is active upon start-up. By default, the temperature sensor is active (TMPSD = 0) and the LUT and both temperature sensors are enabled (LUTDIS = 0, REN = 1 and LEN = 1). Also by default, the temperature overwrite (TMPOW) and DAC overwrite (DACxOW) bits are cleared.
In autonomous mode, the device begins temperature measurements at start-up. Each temperature sensor update triggers the ALU to recalculate the output using the user-defined coefficients, polarity, and BASE value stored in the LUT pages. The ALU output is passed on to the DAC LUT register that ultimately drives the DAC input.
The device remains in autonomous operation unless the data path is overwritten, the LUT is disabled (LUTDIS = 1), or the temperature sensor is powered down (TMPSD = 1). If the LUT is disabled or the temperature sensor is powered down, the DAC output remains at the last calculated value. The device automatically returns to autonomous operation after being reconfigured properly.