SLASFM1A June 2025 – December 2025 AFE10004-EP
PRODUCTION DATA
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| ALMINEN | PAONDIS | RESERVED | RESERVED | DAC3OFF | OUT2OFF | OUT1OFF | DAC0OFF |
| R/W-0h | R/W-1h | R-0h | R-0h | R/W-1h | R/W-1h | R/W-1h | R/W-1h |
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| RESETCMD[1:0] | RESERVED | AMCINT | DRVENRLS | PAONRLS | DACHCRLS | DACRLS | |
| R/W-0h | R-0h | R/W-0h | R/W-0h | R/W-0h | R/W-0h | R/W-0h | |
| LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 15 | ALMINEN | R/W | 0h | ALARMIN functionality for RESET pin 1 = ALARMIN. 0 = RESET. |
| 15 | PAONDIS | R/W | 1h | PA_ON alarm control 0 = PA_ON is unaffected by an alarm event. 1 = PA_ON is set low during an alarm event. |
| 11 | DAC3OFF | R/W | 1h | DAC3 alarm control 0 = DAC3 is unaffected by an alarm event. 1 = DAC3 is switched OFF during an alarm event. |
| 10 | OUT2OFF | R/W | 1h | OUT2 alarm control 0 = OUT2 is unaffected by an alarm event. 1 = OUT2 is switched OFF during an alarm event. |
| 9 | OUT1OFF | R/W | 1h | OUT1 alarm control 0 = OUT1 is unaffected by an alarm event. 1 = DAC3 is switched OFF during an alarm event. |
| 8 | DAC2OFF | R/W | 1h | DAC0 alarm control 0 = DAC0 is unaffected by an alarm event. 1 = DAC0 is switched OFF during an alarm event. |
| 7:6 | RESETCMD[1:0] | R/W | 0h | Reset command 00 = No operation. 01 = Wait for end of temperature conversion. 10 = Release DACs. 11 = Release DACs from start-up current mode. |
| 4 | AMCINT | R/W | 0h | AMC interrupt mode 0 = Normal operation. 1 = Sets device in interrupt mode where the automatic reset control signals are ignored. |
| 3 | DRVENRLS | R/W | 0h | DRVEN control when device is set in interrupt mode 0 = Forces all internal DRVEN switch control signals to zero. 1 = Enables control of the DRVEN signals. |
| 2 | PAONRLS | R/W | 1h | PA_ON control when device is set in interrupt mode 0 = PA_ON pin is forced low. 1 = PA_ON pin is forced high. |
| 1 | DACHCRLS | R/W | 1h | DAC output current control when device is set in interrupt mode 0 = DACs are forced into start-up current mode. 1 = DACs are released from start-up current mode. |
| 0 | DACRLS | R/W | 1h | DAC output control when device is set in interrupt mode 0 = DACs input code is forced to all zeros. 1 = DACs input code can be accessed. |