SLASFM1A June 2025 – December 2025 AFE10004-EP
PRODUCTION DATA
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| BUSY | LHIGH | LLOW | RHIGH | RLOW | OPEN | RESERVED | RESERVED |
| R-0h | R-0h | R-0h | R-0h | R-0h | R-0h | R-0h | R-0h |
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| TMPSTAT | PAON | EECRC | SPICRC | EERDY | DED | SEC | GAN |
| R-0h | R-0h | R-0h | R-0h | R-0h | R-0h | R-0h | R-0h |
| LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 15 | BUSY | R | 0h | Temperature ADC status indicator 1 = ADC is converting 0 = ADC is not converting |
| 14 | LHIGH | R | 0h | Local temperature high limit status indicator 1 = Local temperature value exceeds the Local Temperature High Limit register value. This bit clears upon reading the Status register providing that the condition causing the over temperature result is no longer present. 0 = Local temperature value does not exceed the Local Temperature High Limit register value. |
| 13 | LLOW | R | 0h | Local temperature low limit status indicator 1 = Local temperature value is below the Local Temperature Low Limit register value. This bit clears upon reading the Status register providing that the condition causing the under temperature result is no longer present. 0 = Local temperature value is not below the Local Temperature Low Limit register value. |
| 12 | RHIGH | R | 0h | Remote temperature high limit status indicator 1 = Remote temperature value exceeds the Remote Temperature High Limit register value. This bit clears upon reading the Status register providing that the condition causing the overtemperature result is no longer present. 0 = Remote temperature value does not exceed the Remote Temperature High Limit register value. |
| 11 | RLOW | R | 0h | Remote temperature low limit status indicator 1 = Remote temperature value is below the Remote Temperature Low Limit register value. This bit clears upon reading the Status register providing that the condition causing the undertemperature result is no longer present. 0 = Remote temperature value is not below the Remote Temperature Low Limit register value. |
| 10 | OPEN | R | 0h | Remote junction open circuit detection 1 = The remote junction is an open circuit. This bit clears upon reading the Status register providing that the condition causing the open circuit is no longer present. 0 = The remote junction is not an open circuit. |
| 7 | TMPSTAT | R | 0h | Temperature alarm status indicator 1 = Temperature exceeds alarm threshold. This bit clears automatically after the temperature alarm bits clear. |
| 6 | PAON | R | 0h | PA_ON status indicator 1 = PA_ON pin is high. 0 = PA_ON pin is low. |
| 5 | EECRC | R | 0h | EEPROM load CRC error indicator 1 = Indicates a CRC error during EEPROM load to the user register space. To clear this bit, write a 1. |
| 4 | SPICRC | R | 0h | SPI command CRC error indicator 1 = Indicates a CRC error during an SPI command. To clear this bit, write a 1. |
| 3 | EERDY | R | 0h | EEPROM ready indicator 0 = The EEPROM BURN is in progress. 1 = The EEPROM BURN is complete |
| 2 | DED | R | 0h | Double error detection status indicator 1 = A double bit error is detected when accessing a LUT register in the operating memory. The error is not corrected. To clear this bit, write a 1. |
| 1 | SEC | R | 0h | Single error correction status indicator 1 = A single bit error is detected when accessing a LUT register in the operating memory. The error is corrected. To clear this bit, write a 1. |
| 0 | GAN | R | 0h | GAN ready indicator 1 = The device is in negative output range operation. 0 = The device is in positive output range operation. |