SLASFM1A June 2025 – December 2025 AFE10004-EP
PRODUCTION DATA
The simplified numeric signal path for a DAC and CLAMP channels is shown in Figure 6-16. The temperature sensor serves as the input to the system. Signal processing is done by the LUT and ALU, and the output is driven to the DAC. The CLAMP input code upper eight bits (CLAMP[12:5]) are automatically controlled so that these bits never exceed the upper eight bits of the code being input to the associated DACs (CLAMP1: DAC[0:1] and CLAMP2: DAC[2:3]). The DAC and CLAMP details are omitted because the DAC and CLAMP provide a conversion from numeric domain to voltage domain only, and do not affect the signal flow.
Figure 6-16 Data
Path