SLASFM1A June 2025 – December 2025 AFE10004-EP
PRODUCTION DATA
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| BYP3 | BYP2 | BYP1 | BYP0 | DAC3OW | DAC2OW | DAC1OW | DAC0OW |
| R-0h | R-0h | R-0h | R/W-0h | R/W-0h | R/W-0h | R/W-1h | R/W-1h |
| LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7 | BYP3 | R/W | 0h | DACx ALU bypass control 0 = ALU output sent to DACx. 1 = Bypass the ALU output. Send BASEx value to DACx. |
| 6 | BYP2 | R/W | 0h | |
| 5 | BYP1 | R/W | 0h | |
| 4 | BYP0 | R/W | 0h | |
| 3 | DAC3OW | R/W | 0h | DACx overwrite control 0 = DACx input is generated by LUT. 1 = DACx input is supplied by the serial interface accessible DACxOW[12:0] data register. |
| 2 | DAC2OW | R/W | 0h | |
| 1 | DAC1OW | R/W | 0h | |
| 0 | DAC0OW | R/W | 0h |