SLASFM1A June 2025 – December 2025 AFE10004-EP
PRODUCTION DATA
The device offers the option to store the device configuration (Page 1), CLAMP overwrite values (Page 2), LUT values (Pages 4 and 5) and the Notepad (Page 15) in the EEPROM (see Figure 6-14). The move of data from the operating memory to the EEPROM (burn) is initiated by writing the program code, 0xE4, to the EEPROM burn register in Page 15.
Ensure that the LUT is disabled before accessing the EEPROM.
A EEPROM burn sequence requires Pages 4, 5, and 15 to be configured before Pages 1 and 2. After the registers in all pages have been configured, initiate an EEPROM burn command by issuing the programming code. The EEPROM burn sequence takes approximately 130ms to complete. The EERDY bit provides the EEPROM burn status.
Avoid reset events during the EEPROM burn sequence because of unpredictable results.
Upon start-up, the device automatically executes a EEPROM data load to the operating memory. An EEPROM load sequence takes approximately 5ms to complete.
To return all registers in the device to factory-default settings after an EEPROM load, write the register clear code (0xAD) to the software reset register. A register clear sequence takes approximately 15µs to complete. Table 6-9 summarizes both EEPROM access operations.
| EEPROM ACCESS | SERIAL INTERFACE OPERATION | PAGE | REGISTER | DATA | COMMENT |
|---|---|---|---|---|---|
| LOAD | N/A | N/A | N/A | N/A | Transfer of data from the EEPROM to the operating memory is done automatically after a reset event. |
| BURN | WRITE | 15 | EEPROM Burn register | 0xE4 | Transfer of data from the operating memory to the EEPROM. |