SLASFM1A June 2025 – December 2025 AFE10004-EP
PRODUCTION DATA
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| RESERVED | RESERVED | HAMMOFF | RESERVED | CR[3:0] | |||
| R-0h | R-0h | R/W-0h | R-0h | R/W-8h | |||
| LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 5 | HAMMOFF | R/W | 0h | Hamming-based SECDED module for LUT data access 0 = Enables the SECDED module 1 = Disables the SECDED module |
| 3:0 | CR[3:0] | R/W | 8h |
Conversion rate selection (see Table 7-20). |
| VALUE | CONVERSIONS PER SECOND | TIME (SECONDS) |
|---|---|---|
| 00h | 0.0625 | 16 |
| 01h | 0.125 | 8 |
| 02h | 0.25 | 4 |
| 03h | 0.5 | 2 |
| 04h | 1 | 1 |
| 05h | 2 | 0.5 |
| 06h | 4 | 0.25 |
| 07h | 8 | 0.125 |
| 08h | 16 (default) | 0.0625 (default) |
| 09h | 32 | 0.03125 |