For the most reliable programming, TI recommends this procedure:
- Apply power to device.
- Program RESET = 1 to reset registers.
- Program RESET = 0 to remove reset.
- Program registers as shown in the register map in REVERSE order from highest to lowest.
- Programming of registers R79 down to R0 (with FCAL_EN = 1) is required.
Registers in this range that are only 1s and 0s
must also be programmed in accordance to the
register map. Do NOT assume that the power on
reset state and the recommended value are the
same. The register descriptions also list a
"Reset" value. This value is actually the
recommended value that must match the main
register map table and is not necessarily the
power on reset value.
- Wait 10 ms
- Program register R0 one additional time with FCAL_EN = 1 to verify that the VCO
calibration runs from a stable state.