For the most reliable programming, TI recommends this procedure:
- Apply power to device.
- Program RESET = 1 to reset registers.
- Program registers as shown in the Register Maps in REVERSE order from highest
address to lowest address.
- Programming of all registers
down to R0 (with FCAL_EN = 1) is required. Even
registers with no documented fields must also be
programmed in accordance to the Register Maps. Do NOT assume that the power on
reset state and the recommended value are the
same.
- Wait 10ms to verify that the internal LDOs has settled down
- Program register R0 one additional time with FCAL_EN = 1 to verify that the VCO
calibration runs from a stable state.