STDA033 October 2026 MSPM0G3105-Q1 , MSPM0G3106-Q1 , MSPM0G3107-Q1 , MSPM0G3505-Q1 , MSPM0G3506-Q1 , MSPM0G3507-Q1 , MSPM0L1227-Q1 , MSPM0L1228-Q1 , MSPM0L2227-Q1 , MSPM0L2228-Q1 , MSPM33C321A
Shielding works by reflection, absorption, and redirection of current. At high frequency, enclosure seams and apertures often dominate material conductivity. A long narrow slot can radiate efficiently because current must detour around it. Bond panels with many short contacts, control aperture dimensions, and route shield current at the connector boundary rather than through circuit ground.
At higher frequency, current crowds nearer a conductor's surface. Higher conductivity and magnetic permeability reduce the penetration depth, but seams and apertures can still dominate enclosure leakage.
Cable filters must be located at the connector so disturbed current is diverted before it enters the board. Common-mode chokes act on common-mode current while allowing differential current to pass; their usefulness depends on mode-conversion sources and parasitic capacitance. Connector pin assignment must place returns beside fast signals and avoid forcing high-frequency current across the connector body.