SLUUCP8A June 2024 – April 2025 BQ41Z50
| Class | Subclass | Name | Type | Min | Max | Default | Unit |
|---|---|---|---|---|---|---|---|
| Gas Gauging | State | Update Status | H1 | 0x00 | 0x0E | 0x00 | Hex |
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| RSVD | RSVD | RSVD | RSVD | QMax | Enable | Update1 | Update0 |
| RSVD (Bits 7–4): Reserved. Do not use. | ||
| QMax update in the field (Bit 3) | ||
| 1 = | Updated | |
| 0 = | Not updated | |
| Enable (Bit 2): Impedance Track™ gauging and lifetime updating enable | ||
| 1 = | Enabled | |
| 0 = | Disabled | |
| Update1, Update0 (Bits 1–0): Update Status | ||
| 0,0 = | Impedance Track™ gauging and lifetime updating is disabled. | |
| 0,1 = | QMax updated | |
| 1,0 = | QMax and Ra table have been updated. | |