SNVSC75B April 2023 – September 2025 LM5171-Q1
PRODUCTION DATA
Each LM5171-Q1 synchronizes to an external clock. Each clock signals has an appropriate phase delay for proper multiphase interleaving operation. The interleave angle between the two phases of each LM5171-Q1 are programmed to 180° or 240° by the OPT pin. The SYNCIN and SYNCOUT are phase shifted by 90° with each other. For higher stage phases (more than 8) a HOST MCU is used to generate SYNCIN pulses for set of each 8 phase block. Table 6-3 summarizes the settings of the external clocks and the OPT pin state for multiphase configurations.
| NUMBER OF PHASES | PHASE SHIFT BETWEEN EXTERNAL CLOCKS FOR MULTIPHASE INTERLEAVING | OPT LOGIC STATE(1) | CH-2 PHASE LAGGING VS CH-1 | NUMBER OF LM5171 CONTROLLERS NEEDED | NUMBER OF EXTERNAL CLOCKS NEEDED |
|---|---|---|---|---|---|
| 2 | 180° | 1 | 180° | 1 | 1 or 0 |
| 3 | 120° | 0 | 240° | 2 | 2 |
| 4 | 90° | 1 | 180° | 2 | 2 |
| 6 | 60° or 120° | 1 | 180° | 3 | 3 |
| 8 | 45° | 1 | 180° | 4 | 2 |