SNVSC75B April   2023  – September 2025 LM5171-Q1

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Timing Requirements
    7. 5.7 Typical Characteristics
  7. Detailed Description
    1. 6.1 Overview
    2. 6.2 Functional Block Diagram
    3. 6.3 Feature Description
      1. 6.3.1  Bias Supplies and Voltage Reference (VCC, VDD, and VREF)
      2. 6.3.2  Undervoltage Lockout (UVLO)
      3. 6.3.3  Device Configurations (CFG)
      4. 6.3.4  High Voltage Inputs (HV1, HV2)
      5. 6.3.5  Current Sense Amplifier
      6. 6.3.6  Control Commands
        1. 6.3.6.1 Channel Enable Commands (EN1, EN2)
        2. 6.3.6.2 Direction Command (DIR1 and DIR2)
        3. 6.3.6.3 Channel Current Setting Commands (ISET1 and ISET2)
      7. 6.3.7  Channel Current Monitor (IMON1, IMON2)
        1. 6.3.7.1 Individual Channel Current Monitor
        2. 6.3.7.2 Multiphase Total Current Monitoring
      8. 6.3.8  Cycle-by-Cycle Peak Current Limit (IPK)
      9. 6.3.9  Inner Current Loop Error Amplifier
      10. 6.3.10 Outer Voltage Loop Error Amplifier
      11. 6.3.11 Soft Start, Diode Emulation, and Forced PWM Control (SS/DEM1 and SS/DEM2)
        1. 6.3.11.1 ISET Soft-Start Control by the SS/DEM Pins
        2. 6.3.11.2 DEM Programming
        3. 6.3.11.3 FPWM Programming and Dynamic FPWM and DEM Change
      12. 6.3.12 Gate Drive Outputs, Dead Time Programming and Adaptive Dead Time (HO1, HO2, LO1, LO2, DT/SD)
      13. 6.3.13 Emergency Latched Shutdown (DT/SD)
      14. 6.3.14 PWM Comparator
      15. 6.3.15 Oscillator (OSC)
      16. 6.3.16 Synchronization to an External Clock (SYNCI, SYNCO)
      17. 6.3.17 Overvoltage Protection (OVP)
      18. 6.3.18 Multiphase Configurations (SYNCO, OPT)
        1. 6.3.18.1 Multiphase in Star Configuration
        2. 6.3.18.2 Daisy-Chain Configurations for 2, 3, or 4 Phases parallel operations
        3. 6.3.18.3 Daisy-Chain configuration for 6 or 8 phases parallel operation
      19. 6.3.19 Thermal Shutdown
    4. 6.4 Device Functional Modes
      1. 6.4.1 Initialization Mode
      2. 6.4.2 Standby Mode
      3. 6.4.3 Power Delivery Mode
      4. 6.4.4 Shutdown Mode
      5. 6.4.5 Latched Shutdown mode
  8. Registers
    1. 7.1 I2C Serial Interface
    2. 7.2 I2C Bus Operation
    3. 7.3 Clock Stretching
    4. 7.4 Data Transfer Formats
    5. 7.5 Single READ From a Defined Register Address
    6. 7.6 Sequential READ Starting From a Defined Register Address
    7. 7.7 Single WRITE to a Defined Register Address
    8. 7.8 Sequential WRITE Starting From A Defined Register Address
    9. 7.9 REGFIELD Registers
  9. Application and Implementation
    1. 8.1 Application Information
      1. 8.1.1 Small Signal Model
        1. 8.1.1.1 Current Loop Small Signal Model
        2. 8.1.1.2 Current Loop Compensation
        3. 8.1.1.3 Voltage Loop Small Signal Model
        4. 8.1.1.4 Voltage Loop Compensation
    2. 8.2 PWM to ISET Pins
    3. 8.3 ISET Clamp
    4. 8.4 Dynamic Dead Time Adjustment
    5. 8.5 Proper Termination of Unused Pins
    6. 8.6 Typical Application
      1. 8.6.1 60A, Dual-Phase, 48V to 12V Bidirectional Converter
        1. 8.6.1.1 Design Requirements
        2. 8.6.1.2 Detailed Design Procedure
          1. 8.6.1.2.1  Determining the Duty Cycle
          2. 8.6.1.2.2  Oscillator Programming (OSC)
          3. 8.6.1.2.3  Power Inductor, RMS and Peak Currents
          4. 8.6.1.2.4  Current Sense (RCS)
          5. 8.6.1.2.5  Current Setting Commands (ISETx)
          6. 8.6.1.2.6  Peak Current Limit (IPK)
          7. 8.6.1.2.7  Power MOSFETS
          8. 8.6.1.2.8  Bias Supply
          9. 8.6.1.2.9  Boot Strap Capacitor
          10. 8.6.1.2.10 Overvoltage Protection (OVP)
          11. 8.6.1.2.11 Dead Time (DT/SD)
          12. 8.6.1.2.12 Channel Current Monitor (IMONx)
          13. 8.6.1.2.13 Undervoltage Lockout (UVLO)
          14. 8.6.1.2.14 HVx Pin Configuration
          15. 8.6.1.2.15 Loop Compensation
          16. 8.6.1.2.16 Soft Start (SS/DEMx)
        3. 8.6.1.3 Application Curves
          1. 8.6.1.3.1 Efficiency and Thermal Performance
          2. 8.6.1.3.2 Step Load Response
          3. 8.6.1.3.3 Dual-Channel Interleaving Operation
          4. 8.6.1.3.4 Typical Start Up and Shutdown
          5. 8.6.1.3.5 DEM and FPWM
          6. 8.6.1.3.6 Mode Transition Between DEM and FPWM
          7. 8.6.1.3.7 ISET Tracking and Pre-charge
          8. 8.6.1.3.8 Protections
    7. 8.7 Power Supply Recommendations
    8. 8.8 Layout
      1. 8.8.1 Layout Guidelines
      2. 8.8.2 Layout Examples
  10. Device and Documentation Support
    1. 9.1 Device Support
      1. 9.1.1 Development Support
    2. 9.2 Receiving Notification of Documentation Updates
    3. 9.3 Support Resources
    4. 9.4 Trademarks
    5. 9.5 Electrostatic Discharge Caution
    6. 9.6 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

ISET Soft-Start Control by the SS/DEM Pins

Place a ceramic capacitor CSS1 between the SS/DEM1 pin and AGND to program ISET1 soft-start time. When EN1 goes low, CSS1 is discharged by the internal pulldown FET, the pulldown FET remains on until the SS/DEM1 voltage falls below 0.3V, which is the threshold voltage indicating the completion of SS/DEM1 discharge. When EN1 goes high, the SS pulldown FET is released, and CSS1 is charged up slowly by 70µA current source, as shown in Figure 6-5. The slow ramping SS/DEM1 voltage overrides the ISET1 voltage during soft-start.

The SS/DEM1 sets the non-inverting input of the gm amplifier to,

Equation 11. V I S E T _ c l a m p = 2 × V S S - 1 V

From the equation, when the SS/DEM1 voltage is less than 1.5V, the non-inverting input of the gm amplifier is less than 1V, CH-1 does not switch.

Similar behaviors apply to SS/DEM2.

As shown in Figure 6-14, SS/DEM1 is pulled low when EN1 is low, DIR1 flips (DIR_OK1=0), shutdown, or OVP is triggered. OVP does not pull SS/DEM2 low.

SS/DEMx pin can be pulled low by external circuit to stop switching. The converter restarts switching once SS/DEMx pin is not pulled down. Pull DT/SD pin low for a latched shutdown.

In multiphase parallel operation, the SS/DEMx pins can be tied together.

LM5171-Q1 Soft-Start Control by the SS/DEMx
          Pins Figure 6-14 Soft-Start Control by the SS/DEMx Pins