SNVSC75B April 2023 – September 2025 LM5171-Q1
PRODUCTION DATA
As shown in Figure 6-24, the LM5171-Q1 includes OVP function, which can be used to monitor either the HV-port, or the LV-port, or a user defined voltage rail, through a resistor divider at the OVP pin.
A resistor divider at the OVP pin sets the OVP threshold. When the OVP pin voltage exceeds the 1V threshold on the rising edge, both HO1 and LO1 are turned off. At the same time CSS1 is discharged, and the CSS1 remains discharged as long as the OVP event lasts. When the OVP voltage falls below 0.9V threshold on the falling edge, the OVP alarm is removed, the SS/DEM1 pulldown is released, and CH-1 resumes operation through a soft-start. See ISET Soft-Start Control by the SS/DEM Pins for details.
Note that OVP only affects CH-1, but not CH-2. Connect SS/DEM1 and SS/DEM2 to enable OVP for both channels. Refer to Figure 6-24 for additional OVP. An open drain comparator discharges SS/DEM1 and SS/DEM2 once the protected railed voltage exceeds the OVP threshold.