DLPU041G April 2016 – July 2024 DLPC230-Q1 , DLPC230S-Q1 , DLPC231-Q1 , DLPC231S-Q1
This value determines whether an additional capacitance value is enabled in the light drive circuit. This value generally changes between continuous mode and discontinuous mode operation, where a small capacitance is used for continuous mode.
| VALUE | DESCRIPTION |
|---|---|
| 0x0 | TPS99000-Q1 CMODE signal = 0 (Typically used for continuous mode) |
| 0x1 | TPS99000-Q1 CMODE signal = 1 (Typically used for discontinuous mode) |