DLPU041G April 2016 – July 2024 DLPC230-Q1 , DLPC230S-Q1 , DLPC231-Q1 , DLPC231S-Q1
This command is used to enable or disable photo feedback mode, configure the minimum COMPOUT low time, and enable or disable the CMODE signal from the TPS99000-Q1.
Write Parameters
| BYTE | BITS | DESCRIPTION |
|---|---|---|
| 1 | 0 | Photo Feedback Mode Enable 0x0: Disable 0x1: Enable |
| 2 | 7:0 | COMPOUT Low Minimum COMPOUT low time = (N+2) * (SEQ_CLK Period) The minimum is 4 SEQ_CLK periods: 0x0 - 0x2 will result in 4 SEQ_CLK periods. |
| 3 | 0 | CMODE Enable This value determines whether an additional capacitance value is enabled in the light drive circuit. This value generally changes between continuous mode and discontinuous mode operation, where a small capacitance is used for continuous mode. 0x0: TPS99000-Q1 CMODE signal = 0 (Typically used for continuous mode) 0x1: TPS99000-Q1 CMODE signal = 1 (Typically used for discontinuous mode) |