DLPU041G April 2016 – July 2024 DLPC230-Q1 , DLPC230S-Q1 , DLPC231-Q1 , DLPC231S-Q1
This command is used to set TPS99000-Q1 discontinuous mode maximum pulse widths.
Write Parameters
| BYTE | BITS | DESCRIPTION |
|---|---|---|
| 1:0 | 15:0 | DM Maximum SEN Pulse Width Defines the maximum time that SEN may remain low in discontinuous mode. Once this time expires, SEN will be forced high by the DLPC230-Q1. Time = N × SEQ_CLK Period (approximately 30 MHz, affected by clock spreading) |