The command is to read or write voltage calibration data. This can be read in SEALED, UNSEALED, and FULL ACCESS modes, and written in UNSEALED and FULL ACCESS modes.
Write applied current to device for calibration purposes. When ManufacturingStatus()[CAL_EN] = 1, device calculates and stores calibration data to produce value written to device in milliamps. Command can be read back to verify accuracy of calibration data. Note: OperationStatus()[AUTOCAL] is deprecated and new status OperationStatus()[CALACT] is added. To verify calibration accuracy send ManufacturerAccess() 0xF081 Output CCADCCal Control resulting in OperationStatus()[CAL] = 1 and verify OperationStatus()[CALACT] = 1 before using command ManufacturerAccess() 0x0343 Current Calibration. Calibration Current Period[8000MS|4000MS|2000MS(default)|1000MS] is used to set the CC1 integration period for calibration purposes.
The command format is as follows:
aaAA
| Value | Description | Unit |
|---|---|---|
| aaAA | Current | mA |