| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| I2C_BCAST_EN[0] | LRA_PERIOD_AVG_DIS[0] | LINEREG_COMP_SEL[1:0] | TRIG_PIN_FUNC[1:0] | MODE[1:0] | |||
| R/W-0 | R/W-1 | R/W-0 | R/W-0 | R/W-0 | R/W-1 | R/W-0 | |
| LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
| BIT | FIELD | TYPE | DEFAULT | DESCRIPTION | |
|---|---|---|---|---|---|
| 7 | I2C_BCAST_EN | R/W | 0 | When enabled, the device responds to peripheral address 0x58 (or 1011000). This is useful for triggering multiple drivers at the same time. | |
| 0 | Haptic Broadcast disable. | ||||
| 1 | Haptic Broadcast enabled. | ||||
| 6 | LRA_PERIOD_AVG_DIS | R/W | 1 | Enables/disables averaging for the resonance reporting located in LRA_PERIOD[9:0] parameter. | |
| 0 | LRA_PERIOD[9:0] reports the average period of the last 4 periods. Uses a shift register preloaded with 0. | ||||
| 1 | LRA_PERIOD[9:0] reports the last period. | ||||
| 5-4 | LINEREG_COMP_SEL[1:0] | R/W | 0 | Applies a compensation factor to compensate for variations of LDO shifting. | |
| 0 | 0% | ||||
| 1 | 2% | ||||
| 2 | 4% | ||||
| 3 | 5% | ||||
| 3-2 | TRIG_PIN_FUNC[1:0] | R/W | 1 | This parameter selects the function of the TRIG/INTZ pin. If this parameter is changed during process execution, the device goes into standby. | |
| 0 | Pin functions as external pulse trigger (input). In this mode, the GO bit can also be used to trigger or cancel processes. | ||||
| 1 | Pin functions as external level trigger - enable (input). In this mode the GO bit cannot be used. | ||||
| 2 | Pin functions as an interrupt (open drain output). In this mode, the GO bit is the only mechanism to trigger and cancel processes. | ||||
| 3 | Reserved | ||||
| 1-0 | MODE[1:0] | R/W | 0 | This parameter is used to select the mode of operation. If the mode is changed during process execution, the device immediately goes into standby. | |
| 0 | RTP Mode | ||||
| 1 | Waveform Sequencer Mode | ||||
| 2 | Diagnostics Routine | ||||
| 3 | Automatic Level Calibration Routine | ||||