SLUUD63A December 2024 – October 2026 BQ41Z90
| Class | Subclass | Name | Type | Min | Max | Default | Units |
|---|---|---|---|---|---|---|---|
| PF Status | Device Status Data | PF Alert A | H1 | 0x00 | 0xFF | 0x00 | Hex |
Description: Accumulated PF flags since PF event
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| QIM | SOTF | COVL | SOT | SOCD | SOCC | SOV | SUV |
| QIM (Bit 7): Qmax Imbalance Failure Detection | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| SOTF (Bit 6): Safety Over Temperature FET Failure Detection | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| COVL (Bit 5):Cell Over Voltage Latch | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| SOT (Bit 4): Safety Over Temperature Detection | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| SOCD (Bit 3): Safety Over Current in Discharge Detection | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| SOCC (Bit 2): Safety Over Current in Charge Detection | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| SOV (Bit 1): Safety Over voltage detection | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| SUV (Bit 0): Safety undervoltage detection | ||
| 1 = | Detected | |
| 0 = | Not Detected | |