SLUUD63A December 2024 – October 2026 BQ41Z90
| Class | Subclass | Name | Type | Min | Max | Default | Units |
|---|---|---|---|---|---|---|---|
| PF Status | Device Status Data | Safety Status B | H1 | 0x00 | 0xFF | 0x00 | Hex |
Description: Accumulated safety flags since PF event
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| DCOT | CUVC | OTD | OTC | ASCDL | ASCD | AOCCL | AOCC |
| DCOT (Bit 7): Delta Cell Over Temperature | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| CUVC (Bit 6): Cell Under Voltage Compensation Detection | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| OTD (Bit 5):Over Temperature during Discharge | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| OTC (Bit 4): Over Temperature during Charge | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| ASCDL (Bit 3): AFE Short Circuit in Discharge Latch detection | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| ASCD (Bit 2): AFE Short Circuit in Discharge detection | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| AOCCL (Bit 1): AFE Over Current in Charge Latch detection | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| AOCC (Bit 0): AFE Over Current in Charge detection | ||
| 1 = | Detected | |
| 0 = | Not Detected | |