SLUUD63A December 2024 – October 2026 BQ41Z90
| Class | Subclass | Name | Type | Min | Max | Default | Units |
|---|---|---|---|---|---|---|---|
| PF Status | Device Status Data | PF Status C | H1 | 0x00 | 0xFF | 0x00 | Hex |
Description: Accumulated PF flags since PF event
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| NTC | 2LVL | AFEC | AFER | FUSE | OCDL | DFETF | CFETF |
| NTC (Bit 7): NTC failure | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| 2LVL (Bit 6): Second Level protection failure | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| AFEC (Bit 5):AFE communication failure | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| AFER (Bit 4): AFE Register access failure | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| FUSE(Bit 3): Chemical Fuse failure | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| OCDL (Bit 2): Over Current in Discharge Latch failure | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| DFETF (Bit 1): Discharge FET failure | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| CFETF (Bit 0): Charge FET failure | ||
| 1 = | Detected | |
| 0 = | Not Detected | |