This command is writable/readable in UNSEALED and FULL ACCESS modes. For calibration purpose, the reference temperature values can be entered to the device by writing this command. When ManufacturingStatus()[CAL_EN] = 1, the device calibrates the measured values of the temperature against the reference values, and stores the calibration data to enhance the accuracy of subsequent measurements. If a reference temperature is written as 0, the calibration process will br skipped for the corresponding measurement, and the prior calibration value stored for the measurement will be preserved. Reading this command returns the calibrated measurements.
The cell voltage data are presented in the following format:
aaAAbbBBccCCddDDeeEEffFFggGGhhHHiill, where
| Value | Description |
|---|---|
| AAaa | Device Internal Temperature (0.1°K) |
| BBbb | TS1 Temperature (0.1°K) |
| CCcc | TS2 Temperature (0.1°K) |
| DDdd | TS3 Temperature (0.1°K) |
| EEee | TS4 Temperature (0.1°K) |
| FFff | TS5 Temperature (0.1°K) |
| GGgg | TS6 Temperature (0.1°K) |
| HHhh | TS7 Temperature (0.1°K) |
| IIii | TS8 Temperature (0.1°K) |