SLUUD63A December 2024 – October 2026 BQ41Z90
| Class | Subclass | Name | Type | Min | Max | Default | Units |
|---|---|---|---|---|---|---|---|
| PF Status | Device Status Data | Safety Alert D | H1 | 0x00 | 0xFF | 0x00 | Hex |
Description: Accumulated safety flags since PF event
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| RSVD | RSVD | OCDL | COVL | UTD | UTC | PCHGC | CHGV |
| RSVD (Bit 7): Reserved. Don't use | ||
| RSVD (Bit 6): Reserved. Don't use | ||
| OCDL (Bit 5):Over Current in Discharge Latch Detection | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| COVL (Bit 4): Cell Over Voltage Latch detection | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| UTD (Bit 3): Under Temperature during Discharge Detection | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| UTC (Bit 2): Under Temperature during Charge Detection | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| PCHGC (Bit 1): Over Precharge Current Detection | ||
| 1 = | Detected | |
| 0 = | Not Detected | |
| CHGV (Bit 0): Over Charging Voltage Detection | ||
| 1 = | Detected | |
| 0 = | Not Detected | |