| Class | Subclass | Name | Type | Min | Max | Default | Unit |
|---|---|---|---|---|---|---|---|
| Calibration | Interconnect Resistance | Cell 1 | I2 | 0 | 1000 | 0 | mΩ |
| Calibration | Interconnect Resistance | Cell 2 | I2 | 0 | 1000 | 0 | mΩ |
| Calibration | Interconnect Resistance | Cell 3 | I2 | 0 | 1000 | 0 | mΩ |
| Calibration | Interconnect Resistance | Cell 4 | I2 | 0 | 1000 | 0 | mΩ |
| Calibration | Interconnect Resistance | Cell 5 | I2 | 0 | 1000 | 0 | mΩ |
| Calibration | Interconnect Resistance | Cell 6 | I2 | 0 | 1000 | 0 | mΩ |
| Calibration | Interconnect Resistance | Cell 7 | I2 | 0 | 1000 | 0 | mΩ |
| Calibration | Interconnect Resistance | Cell 8 | I2 | 0 | 1000 | 0 | mΩ |
| Calibration | Interconnect Resistance | Cell 9 | I2 | 0 | 1000 | 0 | mΩ |
| Calibration | Interconnect Resistance | Cell 10 | I2 | 0 | 1000 | 0 | mΩ |
| Calibration | Interconnect Resistance | Cell 11 | I2 | 0 | 1000 | 0 | mΩ |
| Calibration | Interconnect Resistance | Cell 12 | I2 | 0 | 1000 | 0 | mΩ |
| Calibration | Interconnect Resistance | Cell 13 | I2 | 0 | 1000 | 0 | mΩ |
| Calibration | Interconnect Resistance | Cell 14 | I2 | 0 | 1000 | 0 | mΩ |
| Calibration | Interconnect Resistance | Cell 15 | I2 | 0 | 1000 | 0 | mΩ |
| Calibration | Interconnect Resistance | Cell 16 | I2 | 0 | 1000 | 0 | mΩ |
Description: These are the interconnect resistance values entered by the user that represents the interconnect resistance between the top of Cell (n-1) and the bottom of Cell (n), plus the interconnect resistance from the bottom of Cell (n) to the gauge. For Cell 1, the interconnect resistance should be between the negative rail of the battery pack to the bottom of Cell 1, plus the interconnected resistance from the bottom of Cell 1 to the gauge. The measured CellVoltage(n) () is compensated for the voltage drop introduced by this resistance.