FSM_CNTR is shown in Table 9-37 and described in Table 9-38.
Return to Table 9-1.
Set fail safe counter and status.
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|---|---|---|---|---|---|---|---|
| FSM_CNTR_SET | FSM_CNTR_STAT | ||||||
| R/W-0000b | RH-0000b | ||||||
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 7-4 | FSM_CNTR_SET | R/W | 0000b | Sets the number of times FS mode enters before action taken. Value is one less than the number of times FS mode is entered. Range is 0-15, representing entering Failsafe mode 1-16 times |
| 3-0 | FSM_CNTR_STAT | RH | 0000b | Reads back the number of time FSM has been entered in a row up to 15. Can be cleared by writing 0h. |