The VCC2 pin provides 5V output with up to
200mA load current. Refer to
Table 10-1 for the external
capacitance requirement on this pin. This pin is short to battery protected and if
connected to VCAN or another CAN transceiver in the ECU, VCC2 must not be taken off
board where a short to battery can take place. There are three monitors on VCC2,
under-voltage (UVCC2), over-voltage (OVCC2) and short to ground (VCC2
SC).
When these faults are detected, an interrupt is provided and the LDO can be turned off.
No mode change takes place. When VCC2 is on and not in a fault state, register 8'h4F[2],
VCC2_STATUS is set to 1b.